The Singular Solution in EP

Acutus Medical Technology

 

AcQMap® System

Learn More

Mapping Modalities

Learn More
 
 

Therapy

Learn More

Transseptal Access

Learn More
 
 

Access

Learn More
 
  • Image.

    Using ultrasound, doctors can acquire more than 115,000 points every minute. This CT-quality scan can be performed in minutes and allows for static views of the anatomy.
  • Visualize.

    Real-time noncontact mapping provides a global chamber view of endocardial activation for the first time. EPs can see electrical activation of the entire chamber as it happens – something never before possible.
  • Identify.

    Thanks to our real-time view, doctors are able to identify locations causing the arrhythmia and plan the best course of action.
  • Ablate.

    With a clear view, precise ablation – specific to each patient’s electrical heart function – can occur. No more generalized anatomical ablations that may or may not affect a patient’s arrhythmia.
  • Confirm.

    Thanks to real-time, beat-by-beat updates, physicians can confirm each ablation produced the desired outcome – giving doctors high confidence that the treatment will help their patient.

Leading the Charge in the EP Revolution Clinical Efficacy and Procedural Efficiency


  • AcQMap® High Resolution Imaging + Mapping System

    Clear and consistent ultra high resolution maps deliver a personalized treatment approach for superior clinical outcomes

  • AcQMap® 3D Imaging + Mapping Catheter

    Complete information, better analysis, increased confidence

    Full chamber, real-time, ultra high resolution anatomy reconstruction

  • Empty

    AcQMap® Patient Electrode Kit

    Precision manufactured for precision orientation

    Engineered specifically for the AcQMap Imaging and Mapping System



Prior to using these devices, please review the Instructions for Use for a complete listing of indications, contraindications, warnings, precautions, potential adverse events, and directions for use.

Map Any Rhythm in < 3 Minutes Unprecedented Speed and Fidelity

Multiple Mapping Modalities

  • Single Position Non-contact Mapping Chaotic rhythms

    Provides high resolution, non-contact, full chamber maps of every beat in stable and unstable rhythm patterns

  • SuperMap™ Stable and slightly variable repetitive rhythms

    Enables mapping of stable, repetitive rhythms with high accuracy in < 3 minutes

  • Contact Mapping Stable, repetitive rhythms

    Multipoint electroanatomic mapping for simple arrhythmias

  • Vein Buildout Tool

    Precisely visualize the PVs

Prior to using these devices, please review the Instructions for Use for a complete listing of indications, contraindications, warnings, precautions, potential adverse events, and directions for use.

Mapping Analysis Tools Confidently Assess Global Conduction and Rapidly Determine Regions of Interest


AcQTrack™

The AcQTrack analysis tool automatically identifies three abnormal conduction patterns that may be drivers and/or maintainers of complex arrhythmias such as AF.

AcQTrack fits seamlessly into electrophysiologists’ workflows to aid in their visual assessment of complex atrial arrhythmias and help to determine potential areas of interest in a personalized treatment approach.

AcQTrack automatically detects three different types of activity: Irregular (yellow); Partial Rotation (green); and Focal (purple)

SlowZone™ Locator

The SlowZone analysis tool represents a pioneering advancement in substrate mapping. It is the first and only mapping algorithm that identifies consistent areas of slow conduction over the entire atrium.

With SlowZone, physicians create one or more maps which the tool then combines into one composite map for analyzing areas of consistent slowing which enables an individualized diagnosis and treatment for each patient.

SlowZone example: Five maps combine into one composite showing areas of consistent slow conduction

AcQBlate FORCE: A Complete Therapy Solution FASTER, SAFER LESIONS

First and Only Irrigated Force Sensing Catheter
with a Gold Tip Electrode

  • AcQBlate® FORCE Sensing Ablation System A COMPLETE THERAPY SOLUTION

    • AcQBlate FORCE Sensing Catheter
    • Qubic Force Module
    • Qubic RF Generator*
    • Qiona Irrigation pump*

    AcQBlate® FORCE Sensing Catheter GOLD TIP ELECTRODE DELIVERS
    FASTER, SAFER LESIONS1,2

    *Made available through Acutus Medical’s
    international alliance with BIOTRONIK

    1 Linhart M. et al. J Cardiovasc Electrophysiol. 2012 Jul; 23(7): 717–21
    2 B. Schmidt, et al. European Heart Journal Volume 34, Issue suppl 1, 1. August 2013

SEEMLESS INTEGRATION WITH ACQMAP 8

Complete End-to-End Cardiac Ablation Procedure within the AcQMap System
  • Complete visualization and configuration of the ablation parameters and procedure directly on the AcQMap user interface

    Ablation integration into the AcQMap system further supports individualized treatment of areas of interest uniquely identified by AcQMap for superior clinical outcomes

Magnetic Steering. Solid Gold Results. The New Gold Standard in Precision Guided Ablation Therapy


  • MagnoFlush™ Irrigated Magnetic Navigation Mapping + Ablation Catheter

    Best-in-class therapeutic device

Acutus and Stereotaxis

Acutus and Stereotaxis have fully integrated AcQMap software with the Stereotaxis robotic ablation system, the only commercially available magnetic robotic system in EP (CE marked and 510k cleared). The synchronized anatomy rotation between the robotics and the imaging system allows precise targeting of pulmonary vein and non-pulmonary vein triggers.

Prior to using these devices, please review the Instructions for Use for a complete listing of indications, contraindications, warnings, precautions, potential adverse events, and directions for use.

Prior to using these devices, please review the Instructions for Use for a complete listing of indications, contraindications, warnings, precautions, potential adverse events, and directions for use.

Taking You Precisely Where You Need to Go


  • AcQGuide® MAX Steerable Sheath

    The Simple Solution for Superior Steering and Handling of 7F to 12F Catheters

    Enhanced maneuverability

  • AcQCross™ Integrated Transseptal Dilator/Needle

    Exchange Less – Reposition with Ease

    The AcQCross product portfolio is owned and distributed by Medtronic. The AcQCross Max 70 product, designed to work with the AcQGuide Max 2.0 sheath, is distributed by Acutus Medical.

  • AcQRef® Introducer Sheath

    Stable and Reliable Reference

    Unipolar Pacing and Recording for VT Diagnosis

Prior to using these devices, please review the Instructions for Use for a complete listing of indications, contraindications, warnings, precautions, potential adverse events, and directions for use.

Revolution, not Evolution

  • What is Charge Density Mapping?

    The ability to view a clear picture of the heart’s electrical activity in real-time is the distinguishing characteristic of the AcQMap System. With other systems, only voltage readings have been used, resulting in a broad, blended view of cardiac activity.

    The AcQMap System minimizes the broad field effect of voltage with multiple points-of-view and proprietary algorithms to calculate charge density. Electrical activation is displayed as a charge density map on a 3D ultrasound-reconstructed surface anatomy. By displaying only the charge density readings without the surrounding sources, the field of view becomes sharper and narrower.